Investigation of heart rate and blood pressure variability, baroreflex sensitivity, and approximate entropy in acute brain injury patients

  • Vasilios Papaioannou, MD, PhD

      Affiliations

    • Department of Anesthesiology and Intensive Care Medicine, Intensive Care Unit, AHEPA Teaching Hospital, Thessaloniki, Greece, 54006
    • Laboratory of Medical Informatics, School of Medicine, Aristotle University of Thessaloniki, Greece, 54124
    • Corresponding Author InformationCorresponding author. Tel.: +302310 437281.
  • ,
  • Maria Giannakou

      Affiliations

    • Department of Anesthesiology and Intensive Care Medicine, Intensive Care Unit, AHEPA Teaching Hospital, Thessaloniki, Greece, 54006
  • ,
  • Nikos Maglaveras

      Affiliations

    • Laboratory of Medical Informatics, School of Medicine, Aristotle University of Thessaloniki, Greece, 54124
  • ,
  • Efthymios Sofianos

      Affiliations

    • Department of Anesthesiology and Intensive Care Medicine, Intensive Care Unit, AHEPA Teaching Hospital, Thessaloniki, Greece, 54006
  • ,
  • Maria Giala

      Affiliations

    • Department of Anesthesiology and Intensive Care Medicine, Intensive Care Unit, AHEPA Teaching Hospital, Thessaloniki, Greece, 54006

published online 06 December 2007.

Abstract 

Purpose

The purpose of the study was to investigate longitudinally over time heart rate (HR) and blood pressure variability and baroreflex sensitivity in acute brain injury patients and relate them with the severity of neurologic dysfunction and outcome.

Methods

Data from 20 brain injured patients due to multiple causes and treated in the intensive care unit were used, with HR and blood pressure recorded from monitors and analyzed on a daily basis. We performed power spectral analysis estimating low frequencies (LF: 0.04-0.15 Hz), high frequencies (HF: 0.15-0.4 Hz), and their ratio and calculated the approximate entropy, which assesses periodicity within a signal and transfer function (TF), that estimates baroreflex sensitivity. Heart rate variance was considered as a measure of HR variability.

Results

Nonsurvivors (brain dead) had lower approximate entropy (0.65 ± 0.24 vs 0.84 ± 0.26, P < .05) and lower variance mean values (0.48 ± 0.54 vs 1.29 ± 0.42 ms2/Hz, P < .01), lower LF and HF minimum values (0.31 ± 0.88 vs 1.11 ± 0.46, P < .01; and 0.27 ± 0.42 vs 0.86 ± 0.30, P < .01, respectively), lower LF/HF (0.22 ± 0.29 vs 0.62 ± 0.28, P < .01), and lower TF mean values (0.43 ± 0.29 vs 1.11 ± 0.74, P < .05) during their whole stay in the intensive care unit in relation with survivors. The mean variance (P < .05), mean TF (P < .05), and mean LF/HF (P < .05) were significantly successful in separating survivors from nonsurvivors.

Conclusions

We conclude that in acute brain injury patients, low variability, low baroreflex sensitivity, and sustained decrease in LF/HF of HR signals are linked with a high mortality rate.

Keywords:: Heart rate variability, Blood pressure variability, Baroreflex sensitivity, Approximate entropy, Acute brain injury

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0883-9441(07)00082-2

doi:10.1016/j.jcrc.2007.04.006

Journal of Critical Care
Volume 23, Issue 3 , Pages 380-386, September 2008