Practical experiences and in vitro and in vivo validation studies with a new gastric tonometric probe in human adult patients☆☆

  • Péter Palágyi, MD

      Affiliations

    • Department of Anesthesiology, University of Szeged, 6720, Hungary
  • ,
  • László Vimláti, MD, PhD

      Affiliations

    • Department of Anesthesiology, University of Szeged, 6720, Hungary
  • ,
  • Krisztina Boda, PhD

      Affiliations

    • Department of Medical Informatics, University of Szeged, 6720, Hungary
  • ,
  • Gyula Tálosi, MD, PhD

      Affiliations

    • Department of Pediatrics University of Szeged, 6720, Hungary
  • ,
  • Domokos Boda, MD, MSci

      Affiliations

    • Department of Pediatrics University of Szeged, 6720, Hungary
    • Corresponding Author InformationCorresponding author. Tel.: +36 62545330; fax: +36 62545329.

published online 11 February 2010.

Abstract 

Purpose

This study provides practical experiences with a new, simple, balloon-free gastric tonometric probe (probe) and reports the results of simultaneous in vitro and in vivo measurements with a conventional, ballooned gastric air tonometer (catheter) and the new device.

Materials and Methods

Ten healthy volunteers and 50 anesthetized surgical patients with different American Society of Anesthesiologists (ASA) scores, scheduled for neurologic, orthopedic, trauma, and cardiac operations, were enrolled in the study. The values of 60 in vitro and, in 12 surgical patients, 101 in vivo paired Pco2 measurements—performed simultaneously with the new tonometric probe and the catheter that was connected to a Tonocap monitor—were compared. The tolerability of the measurement with the new probe was examined, and the results of gastric tonometry and, in surgical cases, the gastric tonometric, end-expiratory, and arterial Pco2 values were registered. The results were evaluated by analysis of variance test. The data of the in vivo paired measurements were evaluated by Bland-Altman analysis.

Results

The use of the probe proved to be well tolerated and easily applicable in the studied cases. The results of 20 measurements obtained in healthy volunteers and those of 520 measurements in the surgical cases correspond to the data obtained with the classical methods published in the medical literature. During in vitro paired measurements, there was a good agreement between the data obtained with the 2 methods; however, in the in vivo studies, the results of measurements performed with the probe were mostly higher.

Conclusions

The differences between the results obtained with the 2 methods might have been caused by the quicker equilibration property of the probe and by the fundamental differences between the 2 methods. The new probe seems to be applicable for routine human measurements.

Keywords: Gastrointestinal tonometry, Carbon dioxide, Partial pressure, Measurement technique, Validation

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 This study forms part of a project funded by the European Union and the Hungarian Ministry of Economic Affairs (GVOP-3.3.1-05/.-2005-0153/3.0) and of the innovation program at the University of Szeged.

☆☆ Abstract presented at the World Congress of the Society of Intravenous Anaesthesia, 2009, Berlin.

PII: S0883-9441(10)00002-X

doi:10.1016/j.jcrc.2009.12.002

Journal of Critical Care
Volume 25, Issue 3 , Pages 541.e9-541.e15, September 2010